LTU/NTU SZ-DOC-W5-1.pd
Operating Manual
ersion: 1.5
Revision: 2002-09-10 86
MP 1 AAAABBBBCCCCDDDDLLLLLLLLLLLLLLLL
MP A 1111
MP B 01111
MP C 01111
MP D 01111
which results in the following configuration:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Multipoint Configuration
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
TS 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3
Nr 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
1 A A A A B B B B C C C C D D D D L L L L L L L L L L L L L L L L
2 --------------------------------
A 1 1 1 1----------------------------
B -1 1 1 1---------------------------
C -1 1 1 1---------------------------
D -1 1 1 1---------------------------
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
and LTU 2 in the same way:
MP 1 LLLLLLLLLLLLLLLLAAAABBBBCCCCDDDD
MP A 01111
MP B 01111
MP C 01111
MP D 01111
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Multipoint Configuration
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
TS 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3
Nr 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
1 L L L L L L L L L L L L L L L L A A A A B B B B C C C C D D D D
2 --------------------------------
A -1 1 1 1---------------------------
B -1 1 1 1---------------------------
C -1 1 1 1---------------------------
D -1 1 1 1---------------------------
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
The E1 output of LTU 1 is connected to the E1 input of LTU 2; the E1 equipment at the LTU side
is connected to the E1 input of LTU 1 and the E1 output of LTU 2.
Note that the number of time slots, which are looped back, has to be 2, 4, 8, or 16.
Komentarze do niniejszej Instrukcji