Schmid Watson Przewodnik Instalacji Strona 74

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 129
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 73
SZ-DOC-W5-1.pdf LTU/NTU
Version: 1.5 Operating Manual
65 Revision: 2002-09-10
7.3.4.5 MODE Command
The MODE command sets the 1p, 2p, 3p and 4p operation between LTU and NTU.
MODE 1: 1p operation enabled
MODE 2: 2p operation enabled
MODE 3: 3p operation enabled
MODE 4: 4p operation enabled
In 3p and 4p mode the Pair Identification has to be taken into account
Operation Specification Rate
Max data rate of E1 user interface 32 x 64kbit/s
Max data rate of nx64 user interface 96 x 64kbit/s
Max user data rate per pair 36x64kbit/s
3p operation
Pair Identification and Cabling No restrictions
Max data rate of E1 user interface 32 x 64kbit/s
Max data rate of nx64 user interface 96 x 64kbit/s
Max user data rate per pair Pair A&B: 30 x 64 kbit/s
Pair C&D: 18 x 64 kbit/s
4p operation
Pair Identification and Cabling Free pair cabling for data
rates up to 72 x 64 kbit/s
Pair crossing AB, CD
allowed for higher data
rates,
Pair crossing ABCD
prohibited, PID alarm will
show up
Table 7-2: 3p and 4p limitations
Przeglądanie stron 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 128 129

Komentarze do niniejszej Instrukcji

Brak uwag