SZ-DOC-W5-1.pdf LTU/NTU
Version: 1.5 Operating Manual
1 Revision: 2002-09-10
1 The Watson 5 Family
The Watson 5 family is a SHDSL/SDSL transmission system compliant to:
ITU-T G.991.2 Annex B (G.shdsl) and
ETSI TS 101 524 (ETSI SDSL).
It is based on a Trellis-coded PAM16 linecode supporting multiple linerates as well as 1 pair, 2
pair, and 4p DSL transmission. It was designed with flexibility and modularity in mind. It
supports both full and fractional E1 data rates, in either framed or transparent mode, Primary-
Rate-Access (PRA) as well as nx64 kbit/s interfaces (V.35, V.36, X.21).
Watson 5 Multiservice offers flexible transmission with data from both frE1 and nx64kbits/s. The
time slots assignments of E1 as well as of nx64kbit/s interface are configurable.
Watson 5 Multipoint LTUs present a versatile platform for point-to-multipoint operations of
multiple NTUs:
A single Multipoint LTU with two E1 interfaces can be connected with up to 4 NTUs in
various configurations.
For applications where the data volume of single links is not a primary concern, LTUs can be
cascaded to enlarge the number of serviceable links.
Maximal data transfer is gained with dual link operation of the multipoint LTU at full E1 rate.
Multipoint features can be flexibly configured such as mapping of the time slots to user
interfaces, line rates of each pair of links, data rates of each link (i.e. time slots).
The Line-Termination-Units (LTU) are available as 19′′ subrack card or as minirack version. The
LTU may be configured (via jumper) as LTU-L or LTU-R. The LTU-R is capable of remotely
powering remote NTUs. The LTU-R is only master configurable, whereas the LTU-L is both
master and slave configurable.
The Network-Termination-Unit (NTU) is available as a tabletop unit or as a minirack version. A
slide switch as either NTU-R or NTU-L may configure the NTU. An NTU-R is remotely powered by
an LTU-R, whereas an NTU-L is powered by a 230V/48V mains adapter.
An Alarm Control Unit (ACU) in the subrack enables the connection of the EIA485-bus, the EIA232
Monitor interface, and the alarm relays.
An optional Control and Management Unit (CMU) in the 19” subrack acts as an SNMP agent and
brings TMN facilities to the system.