LTU/NTU SZ-DOC-W5-1.pd
f
Operating Manual
V
ersion: 1.5
Revision: 2002-09-10 54
SEG-B: Segment defect alarm indication if regenerators present on channel B
LOOPREG: Regenerator loopback active
BERT: BER test activated
CLD-A Current limit detection on channel A
CLD-B Current limit detection on channel B
PID Display a pair mismatch when operating in 4p mode (master only)
7.3.3.4 ALARM H Command
A.) Alarm H command without time adjustment.
The ALARM H command displays alarm events of the past with a time stamp based on the
internal system time of the LTU. The time stamp shows the number of days elapsed and the
system time in format 24-hour:minute at the occurrence instant of the event.
This relative LTU system time is set to zero by each RESET command or power-on.
LTU_10_FMM> ALARM H
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Alarm History (day:hour:min)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+0:00:00 LOS-S alarm on
+0:00:00 remote alarm on
+0:00:02 LOS-S alarm off
+0:00:02 remote alarm off
~~~~~~~~~~~~~~~~~~~~~~~End of Alarm History~~~~~~~~~~~~~~~~~~~~~~~
LTU_10_FMM>
B.) Alarm H command with time adjustment.
Additional entering of the actual time in format 24-hour:minute when calling the ALARM H
command will modify the displayed time stamp to real time representation.
On basis of the time declaration entered by the user and the LTU's internal system time, the
event is marked with the number of days elapsed and the real time of the occurrence instant
in format 24-hour:minute
LTU_10_FMM> ALARM H 14:23
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Alarm History (day:hour:min)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+0:14:18 LOS-S alarm on
+0:14:18 remote alarm on
+0:14:20 LOS-S alarm off
+0:14:20 remote alarm off
~~~~~~~~~~~~~~~~~~~~~~~End of Alarm History~~~~~~~~~~~~~~~~~~~~~~~
LTU_10_FMM>