Operating Manual
V
ersion: 1.5
Revision: 2002-09-10 114
13 Diagnostics and Troubleshooting
13.1 Test Loops
Standard Test Loops
The test loops can be activated via the monitor interface for both the master and the slave side.
However, only one test loop can be activated at any one time. Activation of a further test loop will
deactivate the previous loop. A system reset will deactivate any pending test loop.
MasterSlave
HDSL
Loop 1 Loop 2
Loop 1
TX
TXRX
RX
User
Interface
User
Interface
Figure 13-1: Standard Test Loops
Notes:
On the slave side, Loop 1 can only be activated locally, while Loop 2 can only be activated
remotely by the master.
Both the “Status Local” LED on the slave and the “Status Remote” LED on the master will be lit
amber when a loopback is active.
On the master side, Loop 1 can only be activated locally. Activating Loop 2 turns on Loop 2 at the
slave station. The “Status Local” LED will be lit amber when Loop 1 is active.
Analog Loopback
To test the DSL UNIT itself, the Analog Loopback can be used. To perform this test, the DSL
cable has to be disconnected from the unit, which must be configured as master. After that the
test can be activated with the appropriate monitor command (see chapter “Monitor”).
With actived Analog Loopback, the DSL transceiver receives the signal of its own transmitter due
to the impedance mismatch in the DSL line transformer. All data of the user interface is looped
back according to the interface settings.
No other test loop can be activated during Analog Loopback. STOPAL command, system reset or
power-up deactivating the Analog Loopback..
If activated, the Analog Loopback sets non-urgent alarms in status off.