SZ-DOC-W5-1.pdf LTU/NTU
Version: 1.5 Operating Manual
57 Revision: 2002-09-10
7.3.3.10 STARTAL Command
The STARTAL command starts the analog loopback:
LTU_01_FMM> STARTAL
01:04:00 analog loopback started
LTU_01_FMM>
Notes:
The system unit must be configured as master for analog loopback operation.
Detach the DSL line before starting the analog loopback. If the analog loopback is started while a
remote station is attached to the DSL line, the remote station signal will interfere with the
loopback signal, causing bit errors on the E1 side.
To return to normal operation, restart the system either by power up or RESET command or use
the STOPAL command.
7.3.3.11 STOPAL Command
The STOPAL command stops the analog loopback
LTU_01_FMM> STOPAL
02:04:00 analog loopback stopped
LTU_01_FMM>
7.3.3.12 TRACETIME Command
The TRACETIME command allows the user to change the trace display repetition time (range: 1 ..
20 sec):
LTU_01_FMM> TRACETIME 3
04:10:30 trace time changed to 03 sec
LTU_01_FMM> TRACETIME 1
04:20:10 trace time changed to 01 sec
LTU_01_FMM>
7.3.3.13 RESET Command
By typing RESET, the system unit will be restarted.
LTU_01_FMM> RESET
05:06:10 system reset
Note:
On a Dual LTU both
systems will be reset.
The RESET command will initiate a restart of the link, while the RESETCARD command will
initiate a complete HW&SW reset. This reset must be confirmed within 30 sec.