Schmid Watson Przewodnik Instalacji Strona 80

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 129
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 79
SZ-DOC-W5-1.pdf LTU/NTU
Version: 1.5 Operating Manual
71 Revision: 2002-09-10
7.4.2.1 CONFIG Command
The CONFIG command displays the configuration of the NTU unit (e.g. V.35):
NTU_CM> CONFIG
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local Configuration Id : nx64 kbit/s V.35
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
V.35
Bit Rate : 32 x 64 = 02048 kbit/s
Clock Mode : Remote
Clock Direction : Codirectional
V.54 Loops : Disabled
Handshake : Disabled
SHDSL
Master/Slave : Slave
Autorestart : Enabled
Power Backoff : Disabled
Payload Rate : 02048 kbit/s
Operating Mode : 1 Pair
Line Rate : 02056 kbit/s
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
NTU_CM>
When both an nx64 kbit/s and an E1 interface are equipped, the configuration display shows first
the E1/PRA configuration and then the nx64 kbit/s configuration:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local Configuration Id : Multiservice
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
2 Mbit/s
Framing : ITU-T G.704
CRC4 : Off
E-Bit Insertion : --
AIS Generation : On
AIS Detection : Off
Data Rate : 11 x 64 = 00704 kbit/s
X.21
Bit Rate : 20 x 64 = 01280 kbit/s
Clock Mode : Remote
Clock Polarity : Normal
Byte Timing : Off
Handshake : Disabled
SHDSL
Master/Slave : Slave
Autorestart : Enabled
Power Backoff : Disabled
Payload Rate : 02048 kbit/s
Operating Mode : 1 Pair
Line Rate : 02056 kbit/s
Warning:
If the nx64 kbit/s interface has to be configured under
remote power conditions, be sure not to
configure it from E1 interface at the remote power limit
. Due to the higher power consumption
of the nx64 kbit/s interface at the NTU side the current limiter at the LTU will possibly operate
thus switching off remote power feeding. Subsequent startup will not be successfull. The
system remains unconfigurable till the NTU is reconfigured locally at the NTU site!