Schmid Watson Przewodnik Instalacji Strona 57

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 129
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 56
LTU/NTU SZ-DOC-W5-1.pd
f
Operating Manual
V
ersion: 1.5
Revision: 2002-09-10 48
Definitions:
1. CRC4: Cyclic redundancy check indicating errored sub-multiframes received on the local
2Mbit/s E1 side.
2. E-bit: CRC-4 indication bit denoting received errored sub-multiframes on the 2Mbit/s E1 side.
3. FAS: Errored Frame Alignment Signal received on the 2Mbit/s E1 side. The criteria for
severely errored seconds (SES) is 28 FAS-Errors per second (in accordance to G.821).
In PRA mode, the G826 E1 command displays the ITU-T G.826 error performance parameters on
the PRA 2Mbit/s:
LTU_01_PM> G826 E1
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
G.826 Error Performance : CRC4_T E-Bit_T CRC4_V3 E-Bit_V3
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Errored Blocks : 00000000 00000000 00000000 00000000
Errored seconds : 00000000 00000000 00000000 00000000
Severely errored seconds : 00000000 00000000 00000000 00000000
ESR [%] : 0.00 0.00 0.00 0.00
SESR [%] : 0.00 0.00 0.00 0.00
BBER [%] : 0.00 0.00 0.00 0.00
Available time : 00524129 00524129 00524107 00524107
Unavailable time : 00000024 00000024 00000046 00000046
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LTU_01_PM>
Definitions:
1. CRC4_T: Cyclic redundancy check indicating errored sub-multiframes received at the NT1
side of the T reference.
2. E-Bit_T: CRC-4 indication bit indicating received errored sub-multiframes at the NT2/TE side
of the T reference point.
3. CRC4_V3: Cyclic redundancy check indicating errored sub-multiframes received at the NT1
side of the V3 reference point.
4. E-Bit_V3: CRC-4 indication bit indicating received errored sub-multiframes at the ET side of
the V3 reference point.
Note:
The G826 E1 command is only available if option 2 (CRC4 processing) or option 4 (CRC4
monitoring) is selected in the configuration.
7.3.2.2 RESETG826 Command
The RESETG826 command sets the G.826 error performance parameters back to zero.
LTU_01_PM> RESETG826
04:35:30 G.826 error performance parameter reset
LTU_01_PM>
7.3.2.3 STARTBER Command
The STARTBER m dir p command starts the pseudo random binary sequence (PRBS) generator
and bit error rate (BER) meter for a duration of m minutes. The test signal generator sends a