SZ-DOC-W5-1.pdf LTU/NTU
Version: 1.5 Operating Manual
55 Revision: 2002-09-10
Note:
Power-on or RESET command will reset the internal system time and will clear all stored events.
The alarm history is limited to 500 alarm messages per system / DSL link and
a maximum
collection time of about 240h.
The current time will be displayed in case the alarm history is empty.
Note:
Once a time adjustment is made with the ALARM H command, this adjustment is stored in the
LTU. Repeated ALARM H command executions without a time adjustment will still display time
stamps calculated on basis of the time declaration previously entered.
Example:
Call of ALARM H command three days after command with time adjustment.
LTU_10_FMM> ALARM H
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Alarm History (day:hour:min)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-3:14:18 LOS-S alarm on
-3:14:18 remote alarm on
-3:14:20 LOS-S alarm off
-3:14:20 remote alarm off
~~~~~~~~~~~~~~~~~~~~~~~End of Alarm History~~~~~~~~~~~~~~~~~~~~~~~
LTU_10_FMM>
7.3.3.5 CLEAR Command
The CLEAR command erases all entries of the event log memory and the time declaration given
by a previously entered ALARM H command with time adjustment.
The internal system time is not resetted by this command.
A new event occuring after the CLEAR command will be displayed with the internal system time
again.
LTU_10_FMM> CLEAR
18:46:10 alarm history cleared
LTU_10_FMM> ALARM H
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Alarm History (day:hour:min)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~~~~~~~~~~~~~~~~~~~End of Alarm History~~~~~~~~~~~~~~~~~~~~~~~
LTU_10_FMM>
7.3.3.6 ACO Command
The ACO (Alarm Cut Off) command enables or disables the alarm relays. When ACO is 'on', all
alarms are disabled and the alarm-relays are inactive. The local alarm LED signalizes a non-
urgent alarm.