Both the Flashloaer program and the application program do not perform a program version
check.
12.2 Download transport via ACU
Download possibilities:
Firmware download to NTU over
• V.24
• V.24 and
DSL link (remote firmware download)
Firmware download to LTU/REG over
• V.24 via ACU2R/ACU48R
Setting the ACU in transparent mode allows program download over ACU’s V.24 Interface.
Local download speed: DSL monitor uses the V.24 interface in 9600bit/s. Program download of
one modem over LTU rack’s V.24 using different baud rate (e.g. 19200), can disturb normal
operation of other modems on the same rack.
Download via ACU
LTU #1
ACU
LTU #2
LTU #12
V.24
Flash Loader on PC
DSL
NTU
NTU REG
NTU