Schmid Watson Przewodnik Instalacji Strona 65

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 129
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 64
LTU/NTU SZ-DOC-W5-1.pd
f
Operating Manual
V
ersion: 1.5
Revision: 2002-09-10 56
Unit ACO Monitor Display Local
LED (1)
Remote
LED (2)
NTU
LED
ON Alarm cutoff activated Orange Green GreenLTU
Master
OFF Alarm cutoff deactivated Green Green Green
ON Alarm cutoff activated Green Orange OrangeNTU
Slave
OFF Alarm cutoff deactivated Green Green Green
LTU_01_FMM> ACO ON
11:03:10 alarm cutoff activated
LTU_01_FMM> ACO OFF
11:11:70 alarm cutoff deactivated
7.3.3.7 LOOP1 Command
The LOOP1 command starts the local loopback:
LTU_01_FMM> LOOP1 ON
01:10:50 Loop 1 activated
LTU_01_FMM>
7.3.3.8 LOOP2 Command
The LOOP2 command starts the remote loopback:
LTU_01_FMM> LOOP2 ON
01:10:50 Loop 2 activated at remote station
LTU_01_FMM>
Note:
The remote loopback is only possible from master side.
7.3.3.9 LOOPREGn Command
The LOOPREGn command starts the loopback in the n
th
regenerator:
LTU_01_FMM> LOOPREG1 ON
29:25:70 regenerator (1) loopback activated
LTU_01_FMM>
Note: This command is available on LTU-R only.