SZ-DOC-W5-1.pdf LTU/NTU
Version: 1.5 Operating Manual
53 Revision: 2002-09-10
7.3.3.3 ALARM Command
The ALARM command displays the actual alarm status:
LTU_01_FMM> ALARM
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local Alarm Status
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LOS-S:off AIS-S:off LOOP1:off ACO:off EXT-LOC:off
LFA-S:off BER-S:off LOOP2:off ALB:off LOOPREG:off
LOSW-A:off BER-A:off SEG-A:off CLD-A:off BERT:off
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
*** Warning: PID alarm detected – use straight pair cabling for this
connection
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LTU_01_FMM>
Options:
T
Turns alarm trace on / off
Definitions
:
LOS-S: Loss of signal at subscriber (E1) side
LFA-S: Loss of frame alignment at subscriber (E1) side
AIS-S: AIS (Alarm Indication Signal) detected at subscriber (E1) side
BER-S: Excessive Block Error Rate on subscriber side
If CRC4 enabled : BER-S = on if more than 805 CRC4 Errors per second.
If CRC4 disabled : BER-S = on if more than 28 FAS Errors per second.
EXT-LOC: Loss of external clock
LFA-V3 Loss of frame alignment at V3-reference point (PRA mode)
AIS-V3 Alarm indication signal at V3-reference point (PRA mode)
LOSW-A Loss of Sync Defect (LOSW defect) on channel A
LOSW-B Loss of Sync Defect (LOSW defect) on channel B
BER-A: SHDSL block-error-rate according G.826 30% on channel A
BER-B: SHDSL block-error-rate according G.826 30% on channel B
LOOP1: SHDSL test loop 1 active (see section 0)
LOOP2: SHDSL test loop 2 active
ACO: Alarm cutoff
ALB: Analog loopback
SEG-A: Segment defect alarm indication if regenerators present on channel A