SZ-DOC-W5-1.pdf LTU/NTU
Version: 1.5 Operating Manual
39 Revision: 2002-09-10
6 Power Concept
6.1 LTU
6.1.1 Power and Grounding
Each plug-in LTU is fed via subrack backplane with (dual) -48V
DC
(referenced to 0V
DC
of the
exchange battery), whereas the minirack LTU is fed via an internal power supply unit. The LTU
generates the used voltages onboard.
The ground reference of all voltages on the secondary side of the LTU’s DC/DC-converter is tied
to FPE (Functional Protective Earth).
Additionally, the plug-in LTU is fed over the backplane with an auxiliary +5V
DC
supply (referenced
to ground) generated on the ACU. The only purpose of this voltage is to drive the alarm circuitry
on each LTU, even in the case of a failure of the LTU's onboard DC/DC-converter.
In case of a failure of the LTU's onboard power supply, both LEDs on the front panel will be
extinguished.
6.2 NTU
6.2.1 Power and Grounding
The ground of an NTU is typically floating when referenced to earth. If an NTU is equipped with
an E1 or nx64 kbit/s user interface, the shields / signal ground of the cables are coupled to the
ground of the NTU.
A slide switch located on the rear side of the housing can select powering of the NTU unit:
Remote powering from the LTU over the DSL line or
Local powering by an external AC/DC or DC/DC adapter
The position of the switch can be changed by means of a small screwdriver. Before operating
the switch, the DSL line connector and the mains adapter connector should be removed.
The supply voltage input is protected against reversal of polarity but not fused. Appropriate
fusing has to be done externally. AC/DC adapters from SZ are recommended.