Schmid Watson Przewodnik Instalacji Strona 84

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 129
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 83
SZ-DOC-W5-1.pdf LTU/NTU
Version: 1.5 Operating Manual
75 Revision: 2002-09-10
7.5 Monitor Commands for LTU Minirack TMN Interface
For Minirack versions of the LTU, the address number of the DSL interface can be set manually
by monitor commands in the Configuration Management (CM) menu.
After power-up of a Minirack LTU always the local monitor main menu appears with the first DSL
system activated (behaviour like a NTU).
Address numbers in range 1-127 can be set independently to the different DSL systems of a
LTU.
The alternatives of running the TMN communication on a 2- or 4-wire bus can be selected in the
CM menu as well. The list below shows the available commands in the Configuration
Management menu of a Minirack LTU.
RESET command, DEFAULT command or power down has no influence on settings made for the
TMN interface.
LTU_01_CM> H
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
CONFIG Display local configuration
G704 [ON,OFF] Set framed mode / transparent mode
CRC4 [ON,OFF] Set CRC4 mode on/off
EBIT [ON,OFF] Set automatic E-Bit insertion on/off
AISGEN [ON,OFF] Set AIS generation on/off
AISDET [ON,OFF] Set AIS detection on/off
EXTCLK [ON,OFF] Set external clock mode on/off
MP [0..3] Set E1 time slot mapping mode
POWER [ON,OFF] Set remote powering on/off
RESTART [ON,OFF] Set autorestart on/off
BACKOFF [ON,OFF] Set power backoff on/off
LINERATE n i a Select line rate (n=[3..36] i=[0,1] a=[0,1])
MODE [1,2] Set SHDSL operating mode
ADDRESS [1..127] Set TMN address
V11WIRES [2,4] Set number of V.11 wires
DEFAULT [0..2] Set default configuration
M(AIN) Return to main menu
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LTU_01_CM>
Przeglądanie stron 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 128 129

Komentarze do niniejszej Instrukcji

Brak uwag