W5-Ethernet-Manual.doc
Version 2.0-01
Watson 5 Ethernet
Operating Manual
Revision: 2006-04-27 3-11
The Ethernet bridge supports the following modes
1) VLAN bridging. Layer 2 VLANs are used to control the traffic. For an Ethernet packet to be sent
from one port to another both ports must be configured to be in the same VLAN. This bridging
mode allows to connect Ethernet user interfaces can be switched to DSL interfaces and vice
versa. It is also possible to switch packets from several DSL interfaces to one Ethernet inter-
face (concentration), to switch packets from an Ethernet or DSL interface to the Management
Processor interface MGMT3 (used for inband management) or to switch packets from DSL to
DSL interface.
2) Transparent bridging. In this mode there is a fixed association between DSL and Ethernet
bridge ports:
Ethernet Bridge
ETH1
ETH2
ETH3
ETH4
DSL1
DSL2
DSL3
DSL4
Ethernet Ports
DSL Ports
Figure 3-5: Transparent bridging
Transparent bridging is similar to the VLAN transparency provided by the Watson 5 Ethernet
tabletop modem, cf. 3.3.2. Transparent bridging lacks the flexibility of VLAN bridging, and in-
band management or linear networks are not supported in this mode. The advantage of trans-
parent bridging is that it is not required to configure any VLAN tags on the bridge, any VID re-
ceived on an Ethernet port will be relayed to the corresponding DSL port and vice versa.
Note that the association between Ethernet and DSL ports is independent of the currently con-
figured multipair mode of the DSL ports. If for example all four DSL wire pairs are combined to
a single DSL span (DSL1) then Ethernet port ETH1 will be associated with DSL port DSL1
while ports ETH2 .. ETH4 and DSL2 .. DSL4 do not carry any traffic at all.
3) Transparent bridging with inband management. This mode is equivalent to the Transparent
bridging mode but allows inband management through the DSL links, cf. 3.5.5.
The bridging modes are controlled by the monitor command BRIDGEMODE.
3.2.3 VLANs
The Watson 5 Ethernet plugin supports VLAN functions according to IEEE 802.1q. Each of the
Ethernet bridge ports (ETH1 .. ETH4, DSL1 .. DSL4, MGMT3) can be member of one or several
VLANs. The maximum number of VLANs is 64. Each VLAN has a VLAN Identifier (VID) between 1
and 4094.
Upon reception of an Ethernet packet at a port its VID is checked against the VIDs of all VLANs this
port is a member of. Packets that do not carry one of these VIDs will be discarded.
For untagged packets the default VID for the port is used to determine VLAN membership.
Packets are only forwarded to ports that are a member of the VLAN of this packet.
Upon transmission the packet will be tagged with the VLAN tag originally received. If the packet
was untagged then the default tag of the receiving port is added to the packet. The port can also be
configured to send the packets untagged.
Przeglądanie stron 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 102 103

Komentarze do niniejszej Instrukcji

Brak uwag

Emerson NetSpan FDP Series podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Nie Emerson NetSpan FDP Series.
Dostarczamy 1 pdf podręczników Emerson NetSpan FDP Series do pobrania za darmo według typów dokumentów: Arkusz Danych






Więcej produktów i instrukcji dla Nie Emerson

Modele Rodzaj dokumentu
ASCO 641 Lighting Control Panel Arkusz Danych   Emerson ASCO 641 Lighting Control Panel Brochures and Data Sheets, 4 strony
67C Rysunki i Schematy   Emerson 67C Drawings & Schematics, 1 strony
Type 1190 Low-Pressure Gas Blanketing Regulator Przewodnik Instalacji   Emerson Type 1190 Low-Pressure Gas Blanketing Regulator Installation Guide, 4 strony
MR105 Rysunki i Schematy   Emerson MR105 Drawings & Schematics, 1 strony
FR959 Instrukcja Właściciela Emerson FR959 Owner's Manual, 5 strony
EZH and EZHSO Series Pressure Reducing Regulators Instrukcja Obsługi   Emerson EZH and EZHSO Series Pressure Reducing Regulators Instruction Manual, 24 strony
Fisher easy-e ET Arkusz Danych   Emerson Fisher easy-e ET Data Sheet, 28 strony
63EG-98HM Instrukcja Obsługi   Emerson 63EG-98HM Instruction Manual [en] , 12 strony
EZR Series Pressure Reducing Regulator Rysunki i Schematy   Emerson EZR Series Pressure Reducing Regulator Drawings & Schematics, 1 strony
CSB400 Rysunki i Schematy   Emerson CSB400 Drawings & Schematics, 1 strony
EZH and EZHSO Series Pressure Reducing Regulators Arkusz Danych   Emerson EZH and EZHSO Series Pressure Reducing Regulators Data Sheet, 1 strony
92B Arkusz Danych   Emerson 92B Data Sheet [en] , 16 strony
Distribution Frame Accessories Arkusz Danych   Emerson Distribution Frame Accessories Brochures and Data Sheets, 1 strony
CSB400 Rysunki i Schematy   Emerson CSB400 Drawings & Schematics, 1 strony
EMC-240B Arkusz Danych   Emerson EMC-240B Brochures and Data Sheets, 28 strony
EZH and EZHSO Series Pressure Reducing Regulators Arkusz Danych   Emerson EZH and EZHSO Series Pressure Reducing Regulators Data Sheet, 28 strony
easy-Drive Arkusz Danych   Emerson easy-Drive Data Sheet, 8 strony
99 Series Commercial/Industrial Regulators Rysunki i Schematy   Emerson 99 Series Commercial/Industrial Regulators Drawings & Schematics, 1 strony
Fisher 4196 Arkusz Danych   Emerson Fisher 4196 Data Sheet, 16 strony
Fisher 8510 Instrukcja Obsługi   Emerson Fisher 8510 Instruction Manual, 8 strony